Compare what’s inside before you choose a supplier. Two products can look identical and use different motor mounts, charging contacts, battery protection circuits, and seals. These differences can explain why a sample charges intermittently, shuts down at its highest setting, or loses a vibration mode over time.
Developing a custom vibrator? Share a 3D product drawing or a photo or link to a style you’re interested in for a free quote.
Lead time: 3 days for in-stock products · 20 days for custom products
1. Motor Selection
For a female vibrator with multiple modes, choose a motor around output, noise, available space, and current demand. Compare rated voltage, startup current, and running current in the finished assembly. For an eccentric rotating mass (ERM) motor, check clearance around the rotating weight across assembly tolerances. Precision Microdrives motor characteristics guide
| Check | Good motor fit | Bad motor fit |
|---|---|---|
| Startup | Starts across the intended operating voltage range | Stalls or resets the device at low charge |
| Mechanical fit | Motor stays secure with moving-part clearance | Motor shifts or the rotating weight rubs |
| Output | Meets output and noise targets in the finished housing | Rattles or feels weak after assembly |
| Current | Startup and running current fit the battery and driver limits | Startup or mode changes cause shutdowns |
Shop-floor takeaway. A motor that works in an open sample can rattle or draw more current once the housing is closed. Share the motor envelope and target modes when you request a free quote.
2. Internal Structure
Factories can use different internal layouts for the same exterior style. Compare how the design locates charging contacts, supports the PCB, retains the motor and battery, and routes wires.
- Charging only at an angle suggests checking contact alignment, connector retention, and tolerance stack-up.
- A mode cutting out during vibration warrants checking pinched leads and intermittent connections.
- Failure after cleaning warrants checking seams, buttons, and the charging interface for possible ingress.
Shop-floor takeaway. Repeated cable attachment can interrupt charging if the connector shifts in the housing. Share a section view or charging-interface photo with your free quote request.
3. Battery Selection
Match battery chemistry and charge voltage to the charger. Compare mAh, allowable discharge current, and voltage sag at motor startup. Verify charger and protection compatibility, including permitted recovery behavior after a low-voltage cutoff. Texas Instruments battery protection guidance
| Check | Good battery fit | Bad battery fit |
|---|---|---|
| Runtime | Meets target in the specified mode | Falls short under the actual duty cycle |
| Startup | Maintains voltage under startup load | Voltage drops enough to reset the controller |
| Charging | Cell, charger, and protection limits align | Charging or recovery fails after protection activates |
| Mechanical fit | Cell is retained clear of hard ribs and pinch points | A rib presses on the cell or traps a lead |
Shop-floor takeaway. A higher mAh rating can still leave you with a device that shuts down at full power. Include your runtime target and highest-load mode when you request a free quote.
4. Silicone Selection
Choose the silicone grade and Shore A hardness for the part. A button membrane needs flex and recovery. A seal needs predictable compression and recovery. An outer sleeve may prioritize tear resistance and finish. Specify the primary cure and assess any post-cure requirement separately. WACKER silicone processing guide
| Check | Properly vulcanized silicone | Uncured or under-cured silicone |
|---|---|---|
| Surface | Meets specified handling and finish criteria | May be tacky, deform, or transfer residue |
| Mechanical response | Can be checked against hardness and recovery targets | May show inconsistent hardness or weak recovery |
| Buttons and seals | Can be tested for repeat actuation and seal performance | Buttons may return slowly or seals lose compression |
| Process evidence | Grade and cure conditions can be checked against records | Cure conditions are out of specification or undocumented |
Shop-floor takeaway. A part can look fine after demolding and fail a button-return or seal-compression check. Flag thin sections and seals when you request a free quote.
What to Check Before Approving a Sample
- Repeat charging connections and check for interruption during normal cable movement.
- Run every mode at full and low charge. Record battery voltage at motor startup if a failure occurs.
- Inspect motor clearance, PCB retention, wire routing, and seal compression in an assembled unit.
- Give suppliers the same runtime, operating modes, charging interface, and acceptance criteria.
Commercial FAQ
What is the minimum order quantity (MOQ)?
Include your target quantity and selected style so the applicable MOQ can be confirmed.
What are your lead times?
Lead times are 3 days for in-stock products and 20 days for custom products.
What material documentation can I request?
List the grade-specific datasheets, material declarations, or test reports you need. Availability can be confirmed for the exact grades and components quoted.
Can I request an NDA before sharing my design?
Include your NDA requirements in the RFQ and request a review before sharing confidential drawings.
Can I get a quote with a reference style?
Yes. Share a photo or link to the style, your target quantity, and any changes you want. If you have a 3D product drawing, include it with your request.